4.6 Initialisation (Reset)
When the A-190 is first switched on after leaving the
factory, its memory is initialised - that is, all parame-
ters are set to their standard default values (see the
table on page 21).
You can always perform a reset, and return the A-190
to these
standard factory settings
. There are two
forms of reset available:
a. Only the parameters marked "
" in the table
are reset.
b.
All the parameters in the table are reset.
For partial reset ‘a’, do the following:
D
Switch the System A-100 off.
D
Keep the menu button
2
pressed, while turning the
A-100 power back on.
The A-190 will confirm the partial reset by flashing
all its LEDs (
8
)
slowly
for about five seconds.
For the full reset ‘b’
, do the following:
D
Switch the System A-100 off.
D
Press and hold buttons
1
to
4
, while turning the
A-100 power back on.
The A-190 will confirm the full reset by flashing all its
LEDs
8
slowly for about five seconds, then quickly
for another five seconds.